The Direct Alarm Supplies NX4 is a professional-grade fire alarm control panel designed for commercial and residential applications. It features 4 zones of conventional detection, built-in sounder circuits, programmable relay outputs, battery backup, LED indicators, keypad programming, event logging, and compliance with relevant fire safety standards. Below are key sections for safety, features, installation, programming, operation, and troubleshooting.
Key components: Main control panel, keypad interface, zone terminals, sounder circuits, relay outputs, battery compartment.
| Feature | Description |
|---|---|
| Zone Inputs | 4 conventional detection zones with monitoring |
| Sounder Circuits | 2 built-in sounder circuits for alarm notification |
| Relay Outputs | Programmable relay for auxiliary control |
| Battery Backup | 24-hour standby battery operation |
| LED Indicators | Zone status, power, fault, alarm indicators |
| Keypad Programming | Intuitive keypad for system configuration |
| Event Logging | Stores last 100 events for diagnostics |
| Fault Monitoring | Continuous monitoring of system integrity |
| Reset Function | System reset after alarm condition |
| Test Mode | Comprehensive system testing capability |
Unpack and inspect contents. Mount in suitable location.
WARNING! Installation must be performed by qualified personnel. Ensure compliance with local fire regulations.
Power on system; follow programming sequence.
CAUTION! Ensure proper wiring and connections before powering on.
Access programming via keypad. Front Panel: Power LED, Alarm LED, Fault LED, Zone LEDs, Reset button, Silence button, Function keys.
Keypad Functions: Numeric keys (0-9), Enter, Clear, Zone select, Program, Test, Reset, Silence.
Programming: Zone configuration, sounder patterns, relay functions, system timers, event logging. Settings: Zone type (smoke/heat/manual), alarm verification, sounder duration, system tests, clock settings.
Zone inputs: Connect detectors using twisted pair cable. Sounder outputs: Connect sounders and strobes. Auxiliary: Relay output for external control.
Tip: Label all cables and connections for easy identification.
Supports comprehensive system programming for various applications.
WARNING! Programming changes should only be made by authorized personnel.
Regular testing ensures system reliability. Test Mode: Comprehensive system testing capability. Maintenance: Scheduled inspections and cleaning.
Note: Maintain testing records as required by regulations.
Disconnect power before cleaning. Use dry, lint-free cloth only; no liquids or chemical cleaners.
CAUTION! Do not use compressed air or vacuum cleaners near detectors. Keep vents clear of dust.
Complies with EN54 standards for fire detection and alarm systems. CE marked for European compliance. Manufactured to ISO 9001 quality standards. Copyright © 2024 Direct Alarm Supplies; all rights reserved. For technical support, visit www.directalarmsupplies.com or contact +44 (0)1234 567890.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Power LED off | No mains power/battery | Check mains supply; verify battery connection. |
| Fault LED illuminated | Zone fault/system error | Check zone wiring; review event log for details. |
| False alarms | Detector contamination | Clean detectors; check for environmental factors. |
| No sounder output | Wiring/settings | Verify sounder connections; check programming. |
| Zone not responding | Wiring/detector fault | Check zone wiring; test individual detectors. |
Reset: Press RESET button to clear alarm conditions.
Service: +44 (0)1234 567890; www.directalarmsupplies.com