Direct Logic Manual

Direct Logic is a comprehensive programmable logic controller (PLC) system designed for industrial automation applications. This manual covers the DL05, DL06, DL105, and DL205 series controllers, providing detailed information on hardware specifications, programming instructions, installation procedures, troubleshooting, and maintenance guidelines for reliable industrial control operations.

1. System Overview 2. Hardware Specifications 3. Installation Guidelines 4. Programming Basics 5. Instruction Set Reference 6. Communication Setup 7. Troubleshooting Procedures 8. Maintenance Schedule 9. Safety Precautions 10. Technical Support

System Overview

Direct Logic PLC systems provide reliable control for various industrial applications with modular design and flexible I/O configurations.

ComponentDescription
CPU ModuleMain processing unit with program memory and communication ports
I/O ModulesDigital and analog input/output modules for signal processing
Power Supply24V DC or 120/240V AC power modules
Communication PortsRS-232, RS-485, Ethernet for network connectivity
Programming SoftwareDirectSOFT programming environment
Expansion BasesAdditional mounting bases for I/O expansion
Memory CartridgeFor program backup and transfer
Real-time ClockTime and date functions for time-based operations
Status IndicatorsLED indicators for power, run, error, and I/O status
Terminal BlocksRemovable connectors for field wiring

Hardware Specifications

Detailed technical specifications for Direct Logic PLC components and modules.

Installation Guidelines

Proper installation procedures ensure reliable operation and system longevity.

  1. Mounting: Install on DIN rail or panel mount in vertical position.
  2. Power Wiring: Connect power supply following voltage specifications.
  3. I/O Wiring: Use proper gauge wires and follow terminal designations.
  4. Grounding: Ensure proper earth ground connection for noise immunity.
  5. Spacing: Maintain minimum 50mm clearance for ventilation.

WARNING! Disconnect all power before installation or wiring. Follow local electrical codes and regulations.

Programming Basics

Introduction to ladder logic programming and DirectSOFT software environment.

  1. Software Installation: Install DirectSOFT programming software on PC.
  2. Communication Setup: Connect programming cable and configure port settings.
  3. New Project: Create new project and select appropriate PLC model.
  4. Program Entry: Use ladder logic editor to create control programs.
  5. Program Download: Transfer program to PLC and verify operation.
  6. Monitoring: Use online monitoring to debug and troubleshoot programs.

Tip: Always create program backups before making significant changes.

Instruction Set Reference

Complete reference of ladder logic instructions available in Direct Logic PLCs.

InstructionDescriptionUsage
XICExamine If ClosedNormally open contact
XIOExamine If OpenNormally closed contact
OTEOutput EnergizeCoil output instruction
OTLOutput LatchLatching output instruction
OTUOutput UnlatchUnlatching output instruction
TONTimer On-DelayTime delay on operation
TOFTimer Off-DelayTime delay off operation
CTUCount UpUp counter instruction
CTDCount DownDown counter instruction
MOVMoveData move instruction

Communication Setup

Configuration of communication ports and network connectivity options.

  1. Port Configuration: Set baud rate, parity, and protocol in system parameters.
  2. Network Addressing: Assign unique node addresses for multi-drop networks.
  3. Protocol Selection: Choose between DirectNET, Modbus RTU, or ASCII protocols.
  4. Driver Installation: Install appropriate communication drivers on host systems.
  5. Testing: Verify communication with ping tests and data monitoring.

Note: Always use shielded communication cables in industrial environments.

Troubleshooting Procedures

Systematic approach to diagnosing and resolving common issues.

SymptomPossible CauseCorrective Action
PLC not respondingPower supply issueCheck power LED; verify voltage; check fuses
Communication failureCable/port configurationVerify cable connections; check port settings; test with known good cable
Inputs not workingWiring/sensor issuesCheck field wiring; verify sensor operation; check input LED status
Outputs not activatingLoad/wiring problemsVerify output LED; check load connections; test with voltmeter
Program errorsLogic/syntax issuesCheck error codes; verify program logic; use programming software diagnostics

Maintenance Schedule

Recommended maintenance procedures for optimal system performance.

CAUTION! Always follow lockout/tagout procedures before maintenance.

Safety Precautions

Critical safety information for installation, operation, and maintenance.

  1. Always disconnect power before working on equipment
  2. Follow proper lockout/tagout procedures
  3. Use appropriate personal protective equipment
  4. Ensure proper grounding of all equipment
  5. Follow local electrical codes and regulations
  6. Keep work area clean and organized
  7. Verify emergency stop functionality regularly

WARNING! Failure to follow safety procedures may result in serious injury or equipment damage.

Technical Support

Contact information and resources for technical assistance and product support.

Note: Have model number and serial number ready when contacting support.